Our products

PEX clips & supports PEX fittings Freeze Guard Hand & pole sanders Drywall hand tools Airlock & sausage packaging

Company

All products How we work Industries About Contact 519-485-5731
‹ All products

Our products

Freeze Guard

Sump pump discharge freeze guard. Keeps the pump flowing when the discharge line freezes.

At a glance

MaterialPVC
ColourWhite
Base connection4″ slip (Sch 40 PVC)
Top connection1-1/2″
Overall height5.75″

In a freeze

When the line freezes, the water still gets out.

A frozen discharge line is how a working sump pump ends up flooding a basement. The Freeze Guard gives the water a second way out.

  1. 1

    Connect it

    The 1-1/2″ discharge drops into the top of the guard, and the 4″ base fits onto the drain pipe above grade.

  2. 2

    Normal flow

    Water runs through the guard and away down the drain line.

  3. 3

    The line freezes

    In a hard freeze, ice can block the buried drain line or the ground around its end.

  4. 4

    The water still gets out

    With the line blocked, water spills out through the louvered ports in the side of the guard instead of backing up the discharge line, so the pump keeps running against an open outlet.

How the Freeze Guard keeps a sump pump discharging in a freeze The 1-1/2 inch discharge drops into the top of the Freeze Guard, which sits on a 4 inch drain pipe above grade. Water runs down the drain line. Ice then blocks the buried line, the water rises in the guard and spills out through the louvered side ports instead of backing up the discharge line. FOUNDATION 1-1/2″ DISCHARGEFROM THE PUMP 4″ DRAIN PIPE TO THE YARD FREEZE GUARD 1CONNECT 2NORMAL FLOW 3THE LINE FREEZES 4WATER STILL GETS OUT
Illustration, not to scale.

The discharge line freezes. The basement floods.

When an outdoor sump pump discharge line ices up, the water has nowhere to go. The pump keeps running against a dead head, pressure backs up the line, and the basement floods. There is no warning and the cleanup is expensive.

The Freeze Guard installs in the discharge line — a 4″ slip base couples to the outlet pipe while the 1-1/2″ top ties into the sump line — surrounding the flow path with an open, slotted cone. Even if the pipe end or the ground around it ices over, water escapes through the side openings, so the pump keeps discharging and the basement stays dry.

Why it is built this way

  • Four rows of large louvered ports plus an open base, so ice forming at any one point never seals the flow
  • Relieves back-pressure, which stops the pump running against a dead head and burning out
  • 4″ slip base and 1-1/2″ top drop into a standard Schedule 40 PVC discharge line
  • White PVC — will not rust, rot or corrode, and stands up to freeze–thaw cycling and UV
  • Private label on existing tooling

Installation

Installation methods.

The Freeze Guard sits on the end of a vertical sump pump discharge line, above grade. The 1-1/2″ discharge drops into the top; the base goes straight into 4″ drain pipe, or into a 4″ SDR 35 adapter for 3″, 4″ or 6″ pipe.

Freeze Guard installation methods Four installations side by side. One: the bottom shoulder of the Freeze Guard inserts straight into 4 inch D2729 sewer and drain pipe. Two to four: the top shoulder inserts into a 4 inch SDR 35 adapter, which then runs to 3 inch pipe through a reducer, straight to 4 inch pipe, or to 6 inch pipe through an increaser. DIRECT WITH A 4″ SDR 35 ADAPTER 1STRAIGHT IN 4″ D2729 SEWER & DRAIN PIPE BOTTOMSHOULDER 2TO 3″ 3″ PIPE VIA A 4×3 REDUCER TOPSHOULDER 3TO 4″ 4″ PIPE SDR 35 OR SCH 40 4TO 6″ 6″ PIPE VIA A 4×6 INCREASER 4″ SDR 35 ADAPTER 1-1/2″DISCHARGE
Freeze Guard installation methods Four installations side by side. One: the bottom shoulder of the Freeze Guard inserts straight into 4 inch D2729 sewer and drain pipe. Two to four: the top shoulder inserts into a 4 inch SDR 35 adapter, which then runs to 3 inch pipe through a reducer, straight to 4 inch pipe, or to 6 inch pipe through an increaser. DIRECT WITH A 4″ SDR 35 ADAPTER 1STRAIGHT IN 4″ D2729 SEWER & DRAIN PIPE BOTTOMSHOULDER 2TO 3″ 3″ PIPE VIA A 4×3 REDUCER TOPSHOULDER 3TO 4″ 4″ PIPE SDR 35 OR SCH 40 4TO 6″ 6″ PIPE VIA A 4×6 INCREASER 4″ SDR 35 ADAPTER 1-1/2″DISCHARGE Freeze Guard installation methods Four installations side by side. One: the bottom shoulder of the Freeze Guard inserts straight into 4 inch D2729 sewer and drain pipe. Two to four: the top shoulder inserts into a 4 inch SDR 35 adapter, which then runs to 3 inch pipe through a reducer, straight to 4 inch pipe, or to 6 inch pipe through an increaser. DIRECT WITH A 4″ SDR 35 ADAPTER 1STRAIGHT IN 4″ D2729 SEWER & DRAIN PIPE BOTTOMSHOULDER 2TO 3″ 3″ PIPE VIA A 4×3 REDUCER TOPSHOULDER 3TO 4″ 4″ PIPE SDR 35 OR SCH 40 4TO 6″ 6″ PIPE VIA A 4×6 INCREASER 4″ SDR 35 ADAPTER 1-1/2″DISCHARGE
Illustration, not to scale.
1

Straight into 4″ pipe

The bottom shoulder inserts directly into 4″ D2729 sewer and drain pipe.

2–4

Through an adapter, 3″ to 6″

The top shoulder inserts into a 4″ SDR 35 adapter, for Schedule 40 PVC or SDR 35 (D3034) sewer and drain pipe. From there the line can run in 3″, 4″ or 6″; 3″ is the minimum.

Below the elbow

4″ min

Of 1-1/2″ inlet pipe between the elbow and the guard.

Above ground

12″ min

Of discharge pipe standing above grade.

Drain pipe range

3–6″

Using a 4″ SDR 35 adapter at the outlet.

Use PVC primer and cement on all connections.

Contact

Ask about this line.

Pricing, availability, private label, or a sample. You get an answer from a person.